1. Analytical Instruments Lab Equipment For Sale
  2. sku: 10527810070547504
  3. ATTOGENE AU2064-03

ATTOGENE AU2064-03 Lateral Flow Assay User Supplied Strep Reporter Particles

Au2064-03 Attogene Universal Lateral Flow Assay For Use With User Supplied Strep Reporter Particles

( Brand: Attogene ), ( Manufacturer Part Number: AU2064-03 ), ( Part Type: Flow ), ( Unit Type: Unit ), ( Country/region Of Manufacture: United States ), ( Intended Use/discipline: Biological Laboratory, Immunology, Internal Medicine, Medical Laboratory, Microbiological Laboratory, Pathology, Pediatrics, Physical Laboratory, Physical Medicine Rehabilitation )

Review ATTOGENE Universal Lateral Flow Assay Use User Supplied Strep Reporter Particles

The Attogene AU2064-03 Lateral Flow Assay is an innovative diagnostic tool designed for detecting Streptococcus pyogenes, also known as group A Streptococcus, in user-supplied Strep reporter particles. This assay employs the gold-standard lateral flow technology, offering rapid and reliable results within 15-30 minutes.

The assay kit comes with all the necessary components for performing the test, including the nitrocellulose membrane, conjugate pad, absorbent pad, and buffer solutions. The user is required to provide Strep reporter particles, which are typically obtained from Strep-expressing cells or bacterial cultures.

The detection of Strep antigens in the user-supplied particles is facilitated by the use of anti-Strep antibody-conjugated gold nanoparticles. These nanoparticles are specifically coated with anti-Strep antibodies, which bind to the target antigens present on the Strep reporter particles.

The lateral flow process begins with the user placing a sample loop filled with the Strep reporter particles onto the sample well. The particles are then wicked through the assay strip by capillary action, carrying the gold nanoparticles with them. As the particles pass over the conjugate pad, the gold nanoparticles transfer to the anti-Strep antibodies immobilized on the pad.

The nanoparticles, now conjugated with the anti-Strep antibodies, continue to move through the assay strip and come into contact with the test line. If Strep antigens are present in the user-supplied particles, they will bind to the gold nanoparticles, forming a visible red line at the test line. The presence of this line indicates a positive result for the detection of Strep antigens.

The assay also includes a control line, which serves as a confirmation that the assay has been performed correctly. A red line appearing at the control line indicates that the assay is valid and that the results obtained at the test line can be relied upon.

The Attogene AU2064-03 Lateral Flow Assay offers several advantages, including ease of use, rapid results, and high sensitivity. It is particularly useful for research applications, such as monitoring Strep expression in laboratory settings or studying the dynamics of Strep infections. With its robust performance and user-friendly design, this assay is an essential tool for any microbiology lab or research facility focusing on Streptococcus pyogenes.

The Attogene AU2064-03 Lateral Flow Assay (LFA) is a diagnostic tool used for the detection of Streptococcus group A (GAS) antigen in various clinical samples. This assay is designed for users to supply their own Streptococcal reporter particles. Here are the pros and cons of buying this product:

Pros:

1. Flexibility: Users have the freedom to use their own Streptococcal reporter particles, allowing them to optimize the assay for their specific research or diagnostic needs.

2. Cost-effective: Purchasing the AU2064-03 assay kit without the pre-coated particles may be more cost-effective for laboratories or researchers that produce their own particles in large quantities.

3. Customizable: Users can customize the assay by using different types or batches of Streptococcal reporter particles, which may improve the sensitivity or specificity of the test.

4. Wide range of applications: The assay can be used for various clinical and research applications, such as screening for GAS infections in clinical samples, monitoring the efficacy of antimicrobial treatments, and studying the molecular mechanisms of streptococcal infections.

Cons:

1. Additional time and effort: Users need to produce and purify their own Streptococcal reporter particles, which may add time and resources to the overall assay process.

2. Higher risk of variability: Using different batches or types of reporter particles may introduce variability into the assay results, making it important for users to carefully control the assay conditions and validate their results.

3. Increased complexity: The additional steps required to produce and use the reporter particles may make the assay more complex than using pre-coated particle LFA kits, which may be more suitable for laboratories or researchers with limited resources or expertise.

In conclusion, the Attogene AU2064-03 Lateral Flow Assay for user-supplied Streptococcal reporter particles offers flexibility, cost-effectiveness, and customizability for laboratories or researchers who produce their own particles in large quantities. However, it also requires additional time, effort, and expertise to produce and use the particles, and may introduce variability into the assay results. Ultimately, the decision to purchase this product depends on the specific needs, resources, and expertise of the laboratory or researcher.

Recommendation:

If you have the necessary resources, expertise, and time to produce and use your own Streptococcal reporter particles, the Attogene AU2064-03 Lateral Flow Assay for user-supplied particles may be a good option for you. It offers the flexibility to customize the assay to your specific needs, and may be more cost-effective in the long run. However, if you prefer a more straightforward and less time-consuming assay, you may consider purchasing a pre-coated particle LFA kit instead.

Details:

Multiplex detection of nucleic Acid DNA or RNA requires the use. Test Line #1: anti please reference strip image, #2 anti FITC/FAM, #3: anti-Dig, #4 Biotin. Kit Components.

Test line: anti-FITC/FAM, Control Line: Biotin option AU2064-01. Test Line #1: anti FITC/FAM, #2: anti-Dig, #3 Biotin. Biotin, FITC/FAM and Dig labelled primers during amplification. No expensive equipment required.

Cost-effective way to screen for further downstream lateral flow assay development. Detection of nucleic Acid DNA or RNA requires the use a biotin and FAM-labelled primer during amplification. Multiplex up to two targets on a single lateral flow strip Choose the option AU2064-02. Attogene Universal Lateral Flow Assay Kits are a convenient ready-to-use kit for quick and cost-effective development of lateral flow dipstick assay detection DNA RNA products.

Formats blank dual purpose conjugate pad. Can be used for development of a lateral flow assay detection variety different molecules such as amplified DNA products from PCR, LAMP and RPA reactions.

part #: au206403 price

  • $170.00

specifications analyticalinstrumentzo:

  • brand: Attogene
  • mpn: Au2064-03
  • part type: Flow
  • unit type: Unit
  • country/region of manufacture: United States
  • intended use/discipline: Biological Laboratory, Immunology, Internal Medicine, Medical Laboratory, Microbiological Laboratory, Pathology, Pediatrics, Physical Laboratory, Physical Medicine Rehabilitation

seller analyticalinstrumentzo:

  • rating: 100.0%
  • # reviews: 17
  • city: Austin, Texas

offer analyticalinstrumentzo:

  • sold: 0
  • availability: In Stock
  • options: Ship-to-home
  • started: April 10, 2025
  • quantity: 3

returns analyticalinstrumentzo:

  • policy: No Returns

payments analyticalinstrumentzo:

  • credit card: Discover
  • wallet: Apple-pay
  • other

shipping analyticalinstrumentzo:

  • class: Standard
  • carrier: USPS
  • service: USPS Ground Advantage
  • type: Fixed
  • cost: $0.00
  • transit: 5-11 Days

general analyticalinstrumentzo:

  • Healthcare, Lab Dental > Medical Lab Equipment, Devices > Blood/Hematology Analyzers
  • condition: New
part type: flow, unit type: unit, country/region of manufacture: united states, intended use/discipline: biological laboratory, immunology, internal medicine, medical laboratory, microbiological laboratory, pathology, pediatrics, physical laboratory, physical medicine rehabilitation,
category: business & industrial > healthcare, lab dental > medical lab equipment, devices > blood/hematology analyzers, sku: 10527810070547504,
Attogene AU2064-03 Is Similar To:
  • (61.6% similar) Cost-effective way to screen for further downstream lateral flow assay development. Test line #1: anti please reference strip image, #2 anti FTC/fame, #3: anti-dig, #4 biotin. Formats strep gold conjugate pad. Can be used for development of a lateral flow assay detection variety different molecules ...(April 4th, 2025)
analyticalinstrumentzo logo
1 offer $170.00 USD
  • New. Offer #1 priced at $170.00 + $0.00 shipping estimate = $170.00* total. (multiplex up to three targets on a single lateral flow strip) option . 10 mL Sample RNase-Free assay running buffer.FREE SHIPPING

Copyright © analyticalinstrumentzo.com