( Brand: Pacific Scientific Instruments ), ( Manufacturer Part Number: 3315-.5-1-AL ), ( Type: Particle Counter )
The 3315 5-1-AL Pacific Met Air Particle Counter is a sophisticated and high-performing instrument designed for scientific and industrial applications. This particle counter operates at a flow rate of 1.0 cfm (cubic feet per minute), making it suitable for a wide range of environments.
The 3315 model features a compact and lightweight aluminum enclosure, which is not only durable but also resistant to corrosion, ensuring long-term use in various environmental conditions. The counter is equipped with a 5-channel laser system, enabling it to detect particles in the size ranges of 0.3, 0.5, 1.0, 2.5, and 5.0 microns with high accuracy and sensitivity.
The 3315 Air Particle Counter boasts a user-friendly interface, featuring a high-resolution LCD display and intuitive menu navigation. This allows operators to easily monitor real-time particle concentration data, set and adjust alarms, and perform routine maintenance tasks. The counter also comes with built-in data logging capabilities, enabling users to store and analyze particle count data over time to identify trends and patterns.
In addition to its advanced features, the 3315 Air Particle Counter is designed with ease of use in mind. It features a quick-change filter system, allowing for easy and convenient filter replacement without the need for specialized tools. The counter is also compatible with a wide range of external data acquisition systems, enabling seamless integration with other monitoring equipment.
In summary, the 3315 5-1-AL Pacific Met Air Particle Counter is a versatile and reliable instrument for measuring and monitoring airborne particles in a variety of applications. Its advanced features, compact design, and user-friendly interface make it an excellent choice for researchers, scientists, and industrial professionals looking for accurate and reliable particle counting data.
Pros of buying a 3315 5-1-AL Pacific Met Air Particle Counter 1.0 CFM Scientific:1. High-precision: This particle counter uses laser technology to accurately count particles as small as 0.3 microns in size, making it suitable for various applications such as cleanroom monitoring, HVAC system testing, and environmental research.
2. Wide particle size range: The 3315 model can detect and measure particles ranging from 0.3 to 10 microns, providing comprehensive data for particle analysis.
3. Durable construction: The instrument's aluminum alloy housing is built to withstand harsh environments and is resistant to corrosion, ensuring long-term reliability and durability.
4. Easy-to-use interface: The 3315 features an intuitive touch screen display, enabling users to easily access and interpret data, adjust settings, and store measurements.
5. Portable design: The compact and lightweight design of the 3315 makes it easy to transport and use in various locations, such as laboratories, cleanrooms, and fieldwork.
Cons of buying a 3315 5-1-AL Pacfic Met Air Particle Counter 1.0 CFM Scientific:1. Cost: The 3315 is a high-end particle counter, and its price may be prohibitive for some users with limited budgets.
2. Power requirements: This model requires a 12V DC power source, which may require additional power supply equipment for some applications.
3. Limited data storage: Although the 3315 comes with an internal memory for data storage, it may not be sufficient for long-term data retention or data transfer to a computer for further analysis.
Recommendation:In conclusion, the 3315 5-1-AL Pacfic Met Air Particle Counter 1.0 CFM Scientific is an excellent choice for users who require high-precision particle counting and analysis in various applications. Its durability, wide particle size range, and easy-to-use interface make it an ideal tool for cleanroom monitoring, HVAC system testing, and environmental research. However, the high cost and power requirements may be limiting factors for some users. If you are looking for a budget-friendly option, you may consider other models with fewer features, but if precision and reliability are your top priorities, the 3315 is a worthy investment.
Please feel free to with any questions. cfm breakthrough long life laser technology extends the average service of instrumentation's to more than ten years. The stored data can be reviewed on front panel, printed or downloaded to a computer. The built-in printer is standard.
Inches operating environment: 12 c to 29 55 f 84 10 85 relative humidity, non-condensing storage 40 50 122 up 98 enclosure type: aluminum the met one 3315 delivers a Review stored records by using the scroll able display.
3 LPN sampling rate with six particle size channels, from m flow rate: 1 cfm alarms can be set for all measurements. 6cm applications: monitor and verify clean rooms test filters track down particle sources monitor: - laminar air flow cabinets paint spray booths food processing areas hospital pharmacies hvac systems indoor quality Iraq aerospace assembly medical device clean room laundries performance specifications: size channels.
This Pacific Scientific Instruments met one particle counter is in excellent condition, has been tested and guaranteed to be fully functional. This easy-to-use software can also be used to schedule the collection of samples by air particle counter. Operating from either ac or batteries, the met one 3315 can provide continuous monitoring of clean areas, storing 2000 readings in its memory buffer.
5 m light source: laser diode 10-year motif pump type: air vacuum, rated for continuous use count display: LCD maximum count: 9,999,999 displayed sample hold time: 1 second to 24 hours alarms: counts cycles: up 100 while in automatic mode location labels: 999, appears on printout data storage: 2000 records, scroll able front panel output: built-in printer, rs-232 port power: rechargeable NIH or ac operation with adapter operating time battery: 3 recharge 2 90, 4 electrical: volts 2a, 50 60 Hz dimensions: 33. Optional environmental sensor data, such as relative humidity, temperature or air velocity are displayed well. Also note photo 5 shows unit successfully running the particle count test.
This item came from a local lab that had surplus inventory. Both ISO and federal standard 209e calculation modes cab be performed, allowing stored data to analyzed according either. 3 LPN zero count: 1 count or less in 5 minutes coincidence loss: than at 400,000 particles ft3 counting efficiency: 50 for 0.
All six particle size channels are displayed simultaneously.